The monitoring image of the elevator warning device is lost but returns to normal after a restart

You are here:

The monitoring image of the elevator warning device is lost but returns to normal after a restart

Published:2022-08-18Views:901Source:本站

(1) Check whether the network cabling structure is reasonable, for example, a single-stage network cable that is too long (generally not exceeding 100 meters), or too many cascaded switches (generally no more than 4 levels).

(2) Check whether the power supply of the elevator warning device is normal. It is recommended to use a DC12V, 1A power supply. A voltage that is too high or too low will affect the normal operation of the elevator warning device; below 10V or above 14V is considered poor power supply.

(3) Check the version number of the elevator warning device and upgrade it to the latest version.